Inverter Growatt ON-GRID MAX60 KTL 3 LV (60KW) Three-phase
Product details
Inverter VALIDATED for PROSUMERS according to ANRE rules Inverter Growatt ON-GRID MAX60 KTL3 LV(60KW) Three-phase (type II SPD, optional AFCI), 6xMPPT, Growatt 10 years warranty.
The Growatt Max 60K TL3 LV three-phase commercial inverter is suitable for PV installations up to 78000Wp. The inverter can produce a total of 60,000 Wp at peak time and does so with a high current of up to 96.6. The inverter contains 6 MPP trackers with 2 connectors each for flexible string configuration.
The Max version has an output of up to 80 kilowatts. With an efficiency range of 99%, maximum energy yield is produced. The inverter is only suitable for commercial PV systems. By using 2 connections per MPP Tracker, voltages are distributed correctly and accurately. The inverter has a maximum of 25 amps per MPP-Tracker
Safety
The inverter has type 2 surge protection for AC and DC input. Both are protected by SPD type 2. This extends the life of the inverter and allows power to be generated for a longer period of time. As a result, your investment is paid back faster. It is possible to activate the Anti-PID of the ACFI function. These are additional options of the Growatt Max series. The inverter is supplied with standard IP65 protection.
Functions
The Growatt Max 60K TL3 LV contains a DC and AC power monitor that runs for 24 hours. This provides additional protection for the AC and DC parts of the inverter. The inverter term comes with a display showing WiFi, LED and application
Maintenance
By intelligently monitoring 12 strings and quickly troubleshooting problems. Smart, local and external maintenance saves service costs and time. This makes the inverter easier to use and more user-friendly. This makes the Max version a perfect choice for your commercial PV installation.
AFCI
AFCI, or Arc-Fault Circuit Interrupter, is a circuit breaker that protects systems from arcing and its consequences. This circuit breaker distinguishes between harmless arcing from normal operation, such as the use of circuit breakers or fuses, and potentially dangerous arcing, for example as a result of faulty wiring. As soon as a potentially harmful arc is detected, the AFCI will open the circuit and interrupt the flow of electricity. This prevents fires due to arcing.
· Over 99% efficiency.
· 6 MPPTs, usable on uneven terrain and larger roofs.
· Safe and reliable.
· Type II surge protection for both DC and AC.
· Integrated anti-PID and AFCI function optional.
· IP65 protection rating.
· DC and AC power supply, 24-hour monitoring.
· Intelligent Sir IV diagnostics.
· Reactive compensation, no SVG device required.
· Full power quality detection, smart grid optimises power quality.
· Easy to maintain.
· 12 strings.
· Intelligent monitoring and quick remote troubleshooting and technical intervention.
2.Specification
Datasheet |
MAX 50KTL3 LV |
MAX 60KTL3 LV |
MAX 70KTL3 LV |
MAX 80KTL3 LV |
Input data (DC) | ||||
Max. recommended PV power (for module STC) |
75000W |
90000W |
105000W |
120000W |
Max.DC voltage |
1100V |
|||
Start voltage |
250V |
|||
Nominal voltage |
585V |
585V |
600V |
600V |
MPPT voltage range |
200V-1000V |
|||
No. of MPP trackers |
6 |
6 |
7 |
7 |
No. of PV strings per MPP tracker |
2 |
|||
Max. input current per MPP tracker |
26A |
|||
Max. short-circuit current per MPP tracker |
32A |
|||
Output data (AC) | ||||
AC nominal power |
50000W |
60000W |
70000W |
80000W |
Max. AC apparent power |
55500VA |
66600VA |
77700VA |
88800VA |
Nominal AC voltage(range*) |
220V/380V, 230V/400V (340-440V) |
|||
AC grid frequency(range*) |
50/60 Hz (45-55Hz/55-65 Hz) |
|||
Max. output current |
80.5A |
96.6A |
112.7A |
128.8A |
Adjustable power factor |
0.8leading 0.8lagging |
|||
THDi |
<3% |
|||
AC grid connection type |
3W+N+PE |
|||
Efficiency | ||||
Max.efficiency |
98.8% |
98.8% |
99% |
99% |
European efficiency |
98.4% |
98.4% |
98.5% |
98.5% |
MPPT efficiency |
99.9% |
|||
Protection devices | ||||
DC reverse polarity protection |
Yes |
|||
DC switch |
Yes |
|||
DC surge protection |
Type II / Type II |
|||
Insulation resistance monitoring |
Yes |
|||
AC short-circuit protection |
Yes |
|||
Ground fault monitoring |
Yes |
|||
Grid monitoring |
Yes |
|||
Anti-islanding protection |
Yes |
|||
Residual-current monitoring unit |
Yes |
|||
String monitoring |
Yes |
|||
AFCI protection |
Optional |
|||
Anti-PID function |
Optional |
|||
General data | ||||
Dimensions (W / H / D) |
860/600/300mm |
|||
Weight |
82kg |
82kg |
86kg |
86kg |
Operating temperature range |
–25°C ... +60°C |
|||
Self-consumption |
< 1W |
|||
Topology |
Transformerless |
|||
Cooling |
Smart air cooling |
|||
Protection degree |
IP65 |
|||
Relative humidity |
0-100% |
|||
Altitude |
4000m |
|||
DC connection |
H4/MC4(Optional) |
|||
AC connection |
Cable gland+OT terminal |
|||
Display |
LED/WIFI+APP |
|||
|
Interfaces: RS485 / USB /WiFi/ RF/GPRS |
Yes/Yes /Optional/Optional/Optional |
|||
Warranty: 5 years / 10 years |
Yes /Optional |
|||
CE , VDE0126, Greece, EN50438, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, CEI 0-16, N4105, BDEW, DRRG, TOR Erzeuger G98/G99, G100, AS/NZS3100, AS4777, UNE217001, UNE206007, PO12.2, NRS 097-2-1, MEA , PEA , KSC8565 | ||||